electric chain hoist is a very popular material handling machine, widely used in various industries. Many problems can be happen to the electric chain hoist caused by improper operation. Based on the studies and responds, the 9 common failures of electric chain hoists and corresponding solutions are presented for your reference.
500kg -35 ton powered trolley electric chain hoist |
500kg powered trolley electric chain hoist Main specifications of electric chain hoist
|
500kg -30 ton manual trolley electric chain hoist for sale |
500kg manual trolley electric chain hoist for sale Main specifications of electric chain hoist
|
0.5-35 ton hook supesnion electric chain hoist for sale |
500kg hook supesnion electric chain hoist for sale Main specifications of electric chain hoist
|
0.5 -30 ton low headroom electric chain hoist for sale |
5 -30 ton low headroom electric chain hoist for sale Main specifications of electric chain hoist
|
As a professional electric chain hoist designer, manufacturer, and supplier, Dongqi Hoist and Crane offers types of electric chain hoists, and related electric hoist services to ensure the easy use of the electric chain hoists.
Please check the 9 common failures and get you’re the solutions to make sure the efficient use of your electric chain hoists.
Failure: Original power line is wrongly connected, resulting in the phase protection starting and hoist unable to operate
Solution: Swap positions of the two phase line
Failure: Power fuse is burned off or switch is off automatically without fuse burned
Solution: check if the current is within the rated scope, change a new fuse or restart the breaker.
Failure: Main line fuse burn off
Solution: check the whole line and change new fuse
Failure: Breakage happen in chain hoist power line or control cabinet or unconnected
Solution: repair the broken cable or change new one or make sure all points in the control cabinet is 100% connected
Failure: Power supply voltage is too low
Solution: measure the voltage value to check if it is less than 10% of the rated power voltage
Failure: The motor makes a sound, but it doesn't rotate.
Solution: Check if motor phase is correct - repair and make sure it is at good insulation state
Failure: Emergency switch has been switched on
Solution: found out the reason why the emergency switch is switched on
Failure: Contactor is not at 100% connected
Solution: operate the chain hoist manually, if the chain hoist can function in the right way, it means problem happened at wire coils or cables, find out the problem location and repair it; if the chain hoist still cannot function, it means problem happen at the main power source, found out the broken contractor and change with new one.
Failure: Contractor coil short circuit
Solution: change new contractor.
Contact us for more information on electric chain hoist problem shooting, and types of electric chain hoist.If you still have problems or doubts on electric chain hoists, please feel free to contact us. WhatsApp/ Wechat: + 86 150 3617 7583. Dongqi’s electric engineer will give you reply within 24 working hours to get your electric chain hoist problems to be solved.